Rolling Office Chair Sliding Resistance Testing Machine according to BIFMA X5.1-2017. The holding fixture is driven by m


Product Details
Technical Parameters

Rolling office chair sliding resistance testing machine

 

EQUIPMENT DESCRIPTION 

Test rig for chair castor durability testing on seating furniture according to BIFMA X5.1-2017. The holding fixture is driven by motor; Chair move forward and back to assess the life durability by setting different parameters in the PLC interface including cycles, standard and so on.


GENERL SPECIFICATIONS

Machine Dimensions: (W x D x H) 2950*1260*930 mm
Power supply source: single-phase, AC220V±10%, 50/60Hz (can be appointed)
Gross Weight: 650k
Load weight: 122kg (270lbf)
Stroke: 762±50 mm
Speed: 10 ± 2 cycles/ min


APPLICATION STANDARDS: BIFMA X5.1-2017


Reference Doc: BIFMA X5.1-2017 section 16 Castor/Chair Base Durability Test-Cyclic

BIFMA X5.1 Castor and Chair Base Test Procedure for Pedestal Base Chairs:

a) The chair or chair base shall be cycled 2,000 cycles over the obstacles as shown in picture 1 and then 98,000 cycles on a smooth, hard surface without obstacles.

b) Evaluate the product in accordance with the acceptance level: there shall be no loss of serviceability.

c) At the conclusion of cycling, a 22 M (5 Ibf). Pull force shall be applied to each caster in line with the castor stem centerline.

d) Evaluate the product in accordance with the acceptance level: no part of the caster shall separate from the chair as a result of the application of the 22 N (5 Ibf.) force.

 

BIFMA X5.1 Castor and Chair Base Test Procedure for Chairs with leg:
 

a) The chair or chair base shall be cycled 2,000 cycles over the obstacles as shown in picture 2 and then 98,000 cycles on a smooth, hard surface without obstacles.

b) Evaluate the product in accordance with the acceptance level: there shall be no loss of serviceability.

c) At the conclusion of cycling, a 22 M (5 Ibf). Pull force shall be applied to each caster in line with the castor stem centerline.

Evaluate the product in accordance with the acceptance level: no part of the caster shall separate from the chair as a result of the application of the 22 N (5 Ibf.) force.


       

 

 

Product Parameters

Driving mode

variable frequency motor and timing belt

Stroke: 

762mm (+ 50mm)

Test speed

8 ~ 12 times / min  

Holder with the up and down adjustment range

80mm500mm

Control mode

PLC and LCD touch screen display

Base barriers block

Can be removed

Accessories

overall test weight 122kg